After reading my earlier post again, I realized I needed to update it....after rdoing the ROLMs for so many years, I ended up working in 1A2 systems as radio stations!!! They still love 1A2s for their studio phones as the controllers were designed to interface to the 1A2 system and control it...
Is it possible on Exchange 2007 to set the REPLY of a mail LISTs (distribution, etc) to auto reply BACK to the list and not the sender? We have an internal mail list for our departmental group...IT claims they cant do it but I swear Ive seen it in earlier versions where when you click REPLY, it...
Last OLDEST switch I was on was a ROLM 8004 MCBX (upgraded from an original RLS 6 in the 70s through 7000 then 8000 software, etc)..I am still working with 824 KSUs (DR5 now--they WERE at DR4!!) and wanting to replace one with a SiemensROLM 9200/HCM200 IF I can find my programming sheets from...
SE cannot be integrated into a 9006i. The SE ONLY supports analog connections and was meant for the 9200 and 150E iirc...In this case, the time in the switch and PM will always be off....HOWEVER, the same is true with PM and using the SLMS BRI interface to the 9006i....IT DOES NOT pass time...
Ok, its been YEARS since I touched a 9200....but got one for free with RP400s and 240E AND PhoneMail so its replacing a POS Norstar 824 KSU that should have NEVER been put it...LCR, etc I can handle.....BUT trying to get the EXTNS to work on the RPs is starting to get to me..I plugged in my 1st...
I KNOW Ive done this before....but cannot remember it.
Where in EMMA do you look to find the WRL of the 9200 CBX???
I have a question on one CPU that has two labels on it and not sure which is the right one.
Thanks!
Your internal DNs is a PRIVATE, not PUBLIC plan....If you access code is 9 to the outside trunks, you should have 91 in your local plan and tell it to delete the 9 (leading digit or 1st digit and send all)...In your PRIVATE plan is where you want 1A routing to the other site (is the network...
Which voicemail is it?? Why not get a Phonemail box with integrates seemlessly with the 300E and uses ISDN BRI connections? I have never done an analog VM connection to the 300E...but then WHY, when Phonemail was made for it?
Has this problem existed always or has it just started?? Sounds like a cut thru timer issue on 20 sec delay...(adding # to the number that is used to call the offsite number may fix that issue; are the analog lines loop or gnd start? Possibly an answer supervision timer)...as to the dropping of...
Looking for either a 9200 with the RP software(131.53.050) or just the CPU with EPROMs board. My 9200 onebox is evidently outdated...and I want to put RPs on this box.
Thanks!
Hmmm my last reply looks a little WRONG...let me reword it (a good night's sleep does wonders!)....
DISA is for OUTSIDE access to your switch...not for Trunk to Trunk TANDEM operation....DISA is nomally setup to allow certain users to dial in from outside (home, cell phone, etc) and be able to...
Hmmm, I remember V4..I was trained on that but our box was running 3.x at the time...We had the BIG rack mount box and it had the 286 cpu.......I never heard of a pre286 processor model..(I do remember upgrading the box from a 286 to 386 cpu/MB at V5.3 or 5.4???; whew!) Maybe that was the...
DISA is not your problem...that is used on inbound trunks (like CO, etc) to another trunk (TIE, CO, etc)...from a TIE to a local CO line, it is FRL that is locking you out..also make sure the inbound side has access to the POOL you want to go out on....DISA (remote access) has nothing to do with...
Cant release it...tried to restore the line and it fails...guess I need to put a card in the slot and maybe that will work...Slot is NOT maint busy and line is NOT assigned to any slot or port! Thats the problem I think..funny thing is all the other lines 818-880 was able to renumber with no...