I have Sun box running Solaris 7 and Disksuite. While doing disk rebuild on the RAID unit, the disk rebuild would get to 90% or more and then a RAID error message would come up on the screen indicating that the disk needed a rebuild. In the past I have had problems with the controller cards...
with the drive attached to the scsi bus, run the following commands:
/usr/sbin/drvconfig
/usr/sbin/devlinks
you should then be able to newfs it and mount it.
Mark
:)