Hello Everyone,
Thank You for your replies in advance.
I have a client with an SL1100 / analog lines out of an Arris Modem from Comcast.
Arris modem has been replaced 2 times,,
Calls on all lines,, randomely,, intermittently,,, will loose for lack of a better term... "signaling" and call will...
Thanks to all in Advance !!!
I have a client with a MICS 0x32 w/7.0 software and CP 150
We have had some fradulent calls on phone bill.... I accidentaly pressed "9" while listening to the AA and it gave me an outside line which i was able to dial locally and long distance. International calling...
Hello,
I have a MICS 0x32 with Call pilot 100....
when a call is xferred to any extension with a VMB.. after the set 4 rings attendent picks up and says "this person cannot be reaced" and put them back in the CCR Tree instead of FWD on Busy/NA to VM. the call does ring at the set and we can...
Hello All,
I have a client with a cp100. We have recently disabled VM and created a new ccr tree to only xfer call to gen delivery after pressing 1 to leave a message. That being said, somehow,,,, calls are still being xfered to the mailboxes.
I have checked table and it is using the proper...
More Questions..
Office Setup -
3 Receptionist's DT343's
9 Users DT333's
The DT343's have the NT303 12 key add-on Module.
I was under the understanding that this would act as a BLF (Busy Lamp Field)
How can I make the Module buttons light up when one of the other extensions is in use?
Thanks
Don
Hello,
I am installing a TDA50G w/ TVA50 VPS. I am having trouble with initial setup. I have the system initialized and 9 phones up and running.
What I am looking for is something that can guide me thru the programming process.
Example:
Step 1 - setup extensions (names, features etc...
Step 2...
I clean up messes all the time. (head turd polisher)...Something of this nature ,,,, if there were correct or at least recent documentation of switch port cabling ,,,All patch cabling would need to be verified.
2 men 40-50hrs each.... 5 days
no documentation.... count on 7 days - 2 men 70hrs...
I have been thrown into a phone system situation that i have no knowledge of. How do you program an Inter-tel Axxess system to recognize a conference room type phone. This phone worked with the current system before the system was moved from 1 building to another. I guess the conference rm phone...
OK, Very cool.. I imiplemented the F801 and it is working.
I am going to leave them using it till the end of the week and see how things go.
Thanks for the help.
Don
Help,
I have a MICS0x32 7.0 software with a CP100 attached.
No AA is being used during the day...only night services.
The receptionist set - 246 has 5 lines that R/A and FNA and FOB to ext 238, and 238 is set to FOB to VM.
the problem ext 246 is having is that when she is on the phone and...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.