Thanks everyone I did resolve it.
After changing my search terms I found the answer.
I used FBUG following the instructions con the web page http://pbxbook.com/meridian/iniloop.html
Thanks again
Chris
Thank you
I have looked for bent pins, I have removed all cards except for the scc and the power supply.
Any ideas welcome and greatly appreciated.
Chris
Hi
Thank you for responding.
I have reseated the daughter boards, the memory, and the dongle. I have also checked the PCMCIA cards.
Same results.
Any other ideas?
Chris
Hi
i just moved a working option 11 from to another (shipped it) and now it will not boot up.
is there any way to recover form this?
I have posted what i see below.
The system has the PCMCIA cards with a backup, however we do not have the keys.
thank you in advance for any help.
Chris...
Thank you for responding
I changed my RCAP settings to match yours (posted below).
There was no change I still only get a name display calling from the Nortel to the Asterisk.
Chris
ADAN DCH 22
CTYP TMDI
CARD 02
PORT 1
DES TOASTERISK
USR PRI
DCHL 2
OTBF 32
PARM RS232...
Hi
I have connected a Asterisk (11) to a Nortel Opt 11 Succession 3. The connect is TIE using QSIG.
Calls are processing however there is no name display calling from the asterisk to the Nortel.
Any help is greatly appreciated.
Below is my Nortel configuration.
Thank you in advance for any...
Thank you for responding.
I did not get the option to change NCNA and NCRD in LD 16.
so I deleted the RSB and recreated it, it did not prompt for those options.
However now I have name display when Nortel calls Asterisk, on the asterisk.
Thank you for responding
I get a SCH0531 error when I try to add ND2.
SCH0531 Action: the RCAP entry point in ovl 16 has been answered NDS when QSUr QSIG GF are not accessible or with an inappropriate interface configured.
Please can someone tell me what I have configured incorrectly?
Chris
Hi
A PRI is connected between a OPT 11 Succession 3 and a Asterisk.
Calls pass OK between the 2 switches, however the name display does not pass through.
I have used IFC = ISGF.
Attached below is my configuration. Please tell me if i have the Nortel settings correct.
Also i need the OPT11...
We just had a failure of a power supply and none of my usual sources have this one. What is the difference between a NTDK70BBE5 and a NTDK70BB as I seem to be able to find those? Or is there another part number that will work?
Or if anyone knows where I can get one in Salt Lake (the switch is...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.