Line Lengths
Analog phones, connected to a Media Gateway MX-ONE Classic/Lite/1U, or legacy MD110 hardware
= 9000 meters when using a 0.5 mm twisted pair cable.
exdnc ,exeqc ksdnc ksexc etc commands were all removed for good reason -they caused corruption !
extee ,then extei
make up a file using regen or rebuild it from scratch
i have attached R13A -
you shouldnt really be using these old cards anyhowhttps://files.engineering.com/getfile.aspx?folder=c0a74163-0286-4457-8af8-0d3a2344476f&file=ELU312R13A.zip
how much data corruption do you think will happen ?
if it was me i would make up regen script files
EXTEE ,then EXTEI
might save a lot of grief
Or if V5 or V6 i would rebuild it off siteat V7 with new SSD
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.