Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations bkrike on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by cdjoek

  1. cdjoek

    CallPilot App bulider- telset recording time is too short

    I have the same issue... has Nortel provided an answer???
  2. cdjoek

    Incoming CLID

    I am not sure where you are located, but 0410 xxx xxxx is not part of North American Numbering Plan. "0" is for operator assisted and international (011 and 01)... If 0410xxxxxxx is dialed it would be an operator assisted call in No Amer...
  3. cdjoek

    Check this problem out

    Does Call Manager go through M-1 or vice versa? Could be lack of answer supv on Octel, EOD timer, etc. What does TRAC...DEV say?
  4. cdjoek

    CLID Issues

    Although the original issue was because the OGT were non-ISDN (PRI), the example has a very critical flaw. You must send a valid (locator database) number for ESA (E911). The proper way to set the block in the example is as follows: ENTRY 10 HNTN 888 ESA_HLCL 2125643210 (Valid E911 number)...
  5. cdjoek

    i2004 @ home

    To set-up an i2004/2002 "at home" a DSL/Cable Modem with a stable IP address (most dynamic rarely change if attached to a router) is required. A VPN router (Netgear or Linksys) is required. Set-up a VPN tunnel between the home private network address and the TLAN (private network address)...