Hi
Can I outpulse an * or # as a part of dialed number over a PRI trunk?. How i can do that?
For example *40*458... as calling number.
It's for activate a feature in CO.
Thank's
Unkalary:
Thanks for you tip!!! It's the solution!.
The system always show me the slot how a analog card (16 ports). I follow you tip and there is no problem now.
I was try to back to digital card and I was build a digital unit on the slot, then I erased it again but this not fix the...
stroked5o:
Yes, I build a unit on the analog card, I try two ways to enable the port.
when I try to enable the unit with enlu x x, the stat shows that the unit is enabled (idle) but without dial tone.
If i try to enable the complete card with enlc X, the system after few seconds show me...
HI
I have replaced a digital card for a analog one in a opt 11C system (rls 25.15) but there is no dial tone on any port.
I was changed the card (a known working card) and anything happens. If I change the card for a digital one on this slot, the ports works nornally.
When I try to enable the...
HI:
The only way I know to adjust meridian in time is a command in LD 2
SDTA x yyyy
where x is the increment positive (1) or negative increment (0)
yyyy is the adjusteent in increment of 100 ms.
TDTA to print the current adjustement
The adjustement is produced during midnight routines...
HI wdhb!
I've MAT tool and receive SNMP traps from few option 11C. The question is, sometimes I receive traps, ie with error code= BSD090 Main Cabinet Power Fail .
The problem is meridian not send a trap when the power is OK.
Exist a way to check from TTY if power is OK? There is some...
Hi:
Somebody can tell me if there is a way to check if power on the swith is up remotely (ie modem)?. I receive BSD090 alarm but i can't check if the power was back.
Thank a lot.
Check TGAR config at the route and TARG on the set that make the transfer. They must be different.
If you have a TIE line check LD 15 CCS DATA
TRY CCRS=TLD (Must be different of FR2)
Hi!
I have a rare problem when somebody make a transfer. We have two Option 11 Rls 25.15 conected togheter with a E1 Tie MFC-R2 and one of the systems is connected to public net with a E1 DID MFC-R2.
The problem is the follow: In a incoming call from DID trunk to a set on first meridian the...
HI
I've a Option 11 C 25.15 with mmail 13 installed. The Hard disk of mmail is damaged (I don't known how) without posibility of recovery.
What do I've to do to reinstall mmail?? What equipment is necesary to do it?.
Thanks in advance.
Set bit signals in E&M with R2?? are you sure? Don't Care
Check in LD 94
REQ PRT
Type R2MF
ICOG OGT --> Outgoing table
TBNO 0 --> The table number used in Route (ld 16)
...
Look at level 2 (LVNO 2) Received signals
RECV 2 OUTT
3 BUSY
4 CONG
5 VACC --> SET THIS IN YOUR...
HI
This is my conf.
Trunk
TN 9 1
DATE
PAGE
DES
TN 009 0 00 01
TYPE RAN
CUST 0
XTRK EXUT
TIMP 600
BIMP 600
AUTO_BIMP NO
RTMB 30 2
DATE 11 SEP 2001
Route
REQ: prt
TYPE: rdb
CUST 0
ROUT 30
TYPE RDB
CUST 00
DMOD
ROUT 30
DES MIRAN
TKTP RAN
NPID_TBL_NUM 0
RTYP CON
GRD...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.