  1. bbonanza

    Magix R3 Caller ID without ID modules

    thanks for the replies. i'm looking at getting an 800gs/ls-id card. hundreds of places on the net sell them refurbished with the 1 year warranty. how can the prices vary from $199 to $899? am i missing something. is there a difference in these?
  2. bbonanza

    Magix R3 Caller ID without ID modules

    I have a Magix R3 clamshelled in Legend, cke5,p/s 391a3,(2)008mlx,(1)400gs/ls/ttr,(1)800gs/ls,(1)012 and MLX-D phones. Can i get caller ID without the ID line modules (assuming i have the service)? I thought i saw my setup would allow it. I don't mind trying if you have an idea. Thanks
  3. bbonanza

    Need Legend R5 Processor replaced

    if i clamshell magix into my legend is my p/s okay? if magix, do i just need "Merlin Magix Release 3.0 Processor" and a clamshell only? thanks
  4. bbonanza

    Need Legend R5 Processor replaced

    I'm resolved that my processor is dead. I need to replace it or upgrade it. Here's what i have;(dead cke3 rel 5),p/s 391a1,(4)008mlx,(1)400gs/ls/ttr,(1)800gs/ls,(1)100D,(2)012,expansion p/s 391a3 and mostly mlx10d's & a few 20d's. Also intuity audix. What i need operational now is;(2)008,the...
  5. bbonanza

    Message LED always on

    i don't you phones, but i have a legend that is similar. i believe there are two ways to turn it on. 1)voice mail, where you retrieve the msgs by dialing your vm. 2)phone msg or notice that you recieve from an internal caller. this one usually list the ext that called asking for a return call...
  6. bbonanza

    Legend R5, Red LED, Moved, Red LED

    should i have voltage out of the admin port? or smdr port?
  7. bbonanza

    Legend R5, Red LED, Moved, Red LED

    no luck. took out all modules leaving ps and processor. removed pin on jumper next to batteries. still boots with red led alarm. and i can't connect with winspm. i'm going to try dos. any suggestions from here?
  8. bbonanza

    Legend R5, Red LED, Moved, Red LED

    thanks for reply. i did try removing the jumper next to the batteries for 10 seconds, but all the modules were mounted. i'll remove them and try that again. then i'll try with spm. will advise.
  9. bbonanza

    Legend R5, Red LED, Moved, Red LED

    p/s 391a1, cke3 rel5,(4)008mlx,(1)400gs/ls/ttr,(1)800gs/ls, (1)100D,(2)012, expansion has 391a3 2 weeks before i scheduled to move to a new location i got an a system alarm (red led on processor) and the phones were locked up. i couldn't get the alarm from the console nor could i reboot to...