Hi MD experts!
Perhaps question is simply but I have no experience with this topic.
Will MD110, which was working in USA, work in Poland? Are there difference, which make it impossible ?
antek
Hi !
Is it possible that DNA is able to use external, other vendor LDAP server to read list of contacts ?
I have found out that only OWS is able to do it.
Dear MD experts!
I have found out that using VSU2 in MD110 I can get Automated Attendant feature. It means that a customer listens to the Voice Answer like "Welcom in Ericsson" and then he can dial the desired extension number.
Normally in MD110 - BC10 I can listen to the Voice Answer and then...
I have question.How can adjust ringing signal diffrent for internal and diffrent for external calls.I adjusted in aspac
ASPAC:PARNUM=1,PARVAL=2; but I don't hear diffrent in ringing signal cadence.
Dear Mr. Johnpoole
I am very thanks for you kindly support.
If you mean by this (you may need to turn on qsig between the two) to open Qsig between the two MD we already open it and if we replace Meridian by MD for test every thing will working well ,also notes that when we dial any analogy...
Hello,
The person he has expert with Meridian option 61 r22 cannot change the rout parameters and he told us the problem from Ericsson and Meridian cannot accept this new parameters, now we still have the same problem with Ericsson PBX and we need urgent help
Meridian option 61programing as...
hi john poole
Sorry I don’t understand and I don’t have experience with Meridian but I have some at Md110, generally I need Full parameter to connect Meridian option 61 with Ericsson MD110 by E1 as network.
Rout from MD110 to Meridian configured as the following
ROCAI: ROU=72,SEL=...
Hi
We have 3 PBX connecting together by ISDN Qsig, one Meridian option 61 and two Ericsson MD110, one from this MD110 is transit Exchange our problem is when we make a call from MD110 (not transit) to Meridian we can see the caller ID at our extension (this call come troughs the transit...
This cable are needed for duplicating ring-Signals to other magazines in which there are PU4DC. In my Alex library there are only PU5DC. I don't know if PU4DC and PU5DC are the same from this point of view.
Hi MD experts!
I can't find in my documentation how to distribute RING SIGNAL from REU board in one magazine to other magazines in the same LIM. Somebody told me that I need cables between PU4DCs in all magazines.
Is it true? What kind of TSR ... cable do I need? What connectors in PU4DC...