Curlycord - Yes, we confirmed it is a Rls 2 NRAM. Next step we are going to replace all of the modules and cards (Combo Cards, DTI Cards). Wish us luck.
Curlycord - Thank you for the feedback. We have removed the 12x0 with the Analog Lines from the system and are going to see how it performs.
Have you had any experience with MICS Systems with 3 PRI's and 12 Analog Lines Active? I was concerned that the line count was too high for the system...
I have a client that is experiencing "system slowdown" at times when calling out. It is a call center environment, with about 60 users - very heavy outbound dialing.
At times, the system seems to bog down. Employees dial, but the digit's don't show up in the display for a couple of seconds...
We have a customer with a MICS SW Version 7.0 (30DEC12 NAT). The system is configured with 2 PRI T1, Combo Card, 1 0x12 with 12 POTS Lines, 1 0x8 Analog Station Module and 4 Station Modules. All 96 Digital Stations are in use, so it is pretty much maxed out. The customer does a lot of calls...
We are trying to get the Automated Attendant to transfer a call off site using the Central Office "Call Transfer" function that is on the phone lines. They system seems to always try to do a trunk to trunk transfer. Is there any way to get the system to generate a flash when one of the options...
Does anyone have the Server Requirements for RCC version 2.45.105 running with Call Pilot 150 version 31.10.36.22?
Any help would be appreciated. Thanks.
Client has a Norstar MICS 7.1 that was upgraded (old main cabinet and peripherals) about 3 years ago. About 6 months ago, they reported system lagging. What happens is at times, when a call is answered, the line remains silent for 5-8 seconds before the caller on the other end of the line is...
We have CP 150 version 31.10.14.22 with about 112 mailboxes in use that keeps seizing up. When it seizes up, no one can access the voice mail system, and it cannot be accessed via the ethernet port. The system stays this way until it is re-booted. We have checked the power supply, and it is...
I have a client that recently connected a remote location to their Opt. 11, rel. 3 PBX. The remote location has a Panasonic PBX. It was supposed to be connected with 2 PRI T1's but the Panasonic and Nortel vendors could not make the PRI's work between the two switches, so they set them up as...
Does anyone know if it is possible to deactivate the page tone that the system emits over handset when doing a page to all handsets? A friend of mine recently had this system installed and called inquiring if it was possible. His vendor is telling him that they cannot get rid of the...
Thanks for the advice. I checked the client priveledges page and noticed another PC which had been registered on the system. I could not get it unregistered from the BCM until it was powered down. Once it was, I was able to register the PC that we wanted to use the PCM on. Thanks for the...
Just installed Personal Call Manager (BCM400 4.0) and the LAN CTE Client on a PC (XP PRO Version 2002 Service Pack 3). I cannot get the Personal Call Manager to work. Here is what I get, in terms of options, when choosing a TAPI line.
RAS PPPoE Line0000
RAS VPN Line 0
WAN Miniport (L2TP)...
cook1082, Merbac - Thank you. We added an expansion module and 4 port Analog Trumk Module, swung the lines to the module from the processor and no more chirps. The problem is fixed. Thank you for your assistance.