Paging, how to make it work with an analogue station port

AVAYA: IPO Office FAQ

Paging, how to make it work with an analogue station port

by  Westi  Posted    (Edited  )
With an amplifier that has a 600 Ohm T/R (Tip and Ring) input:

connect the analog station port directly to the T/R input of the amplifier
make sure there is a User that matches the port (we make it 234 here)

Change the Extension port setting in the Analogue Tab to be "Paging Speaker"

create a shortcode
*25
Dial Paging
234
Line ID doesn't matter

You can now add the user created for the paging extension to a huntgroup and can page the entire huntgroup with another "Dial Paging" shortcode having the group extension in the Telephone Number field

Done Usually

Should you have a non telephony paging amplifier then your impedance is around 10kOhm and you will need to use impedance matching devices like the [link http://www.bogen.com/products/pdfs/specialelectronicspdfs/WMT1Am_old.pdf]WMT1A[/link] which is simply put between the IPO station port and the amplifier input. This device can also be used if you need to have several inputs and use the AUX input on a regular amp.

hope that helped