Norstar Wiring

What is the correct cable pinouts for MICS Modules by jerryreeve
Posted: 16 Apr 02 (Edited 1 Apr 09)

Amphenol        Station Module    
Connector            
Pair    Color    Telephone    Port
1     Wh/Bl    1     X01
2     Wh/Or    2     X02
3     Wh/Gn    3     X03
4     Wh/Br    4     X04
5     Wh/Sl    5     X05
6     Rd/Bl    6     X06
7     Rd/Or    7     X07
8     Rd/Gn    8     X08
9     Rd/Br    9     X09
10    Rd/Sl    10    X10
11    Bk/Bl    11    X11
12    Bk/Or    12    X12
13    Bk/Gn    13    X13
14    Bk/Br    14    X14
15    Bk/Sl    15    X15
16    Yl/Bl    16    X16
17    Yl/Or     ---     ---
18    Yl/Gn     ---     ---
19    Yl/Br     ---     ---
20    Yl/Sl     ---     ---
21    Vi/Bl     ---     ---
22    Vi/Or     ---     ---
23    Vi/Gn     ---     ---
24    Vi/Br     ---     ---
25    Vi/Sl     ---     ---
            
Amphenol            Trunk Module
Connector            LS DS   CI Card
Pair    Color    Port    Line/Connection
1     Wh/Bl    X01    slot 1 line 1/module line 1
2     Wh/Or    X02    slot 1 line 2/Module line 2
3     Wh/Gn     ---     ---
4     Wh/Br     ---     ---
5     Wh/Sl    X03    slot 1 line 3/Module line 3
6     Rd/Bl    X04    slot 1 line 4/Module line 4
7     Rd/Or     ---     ---
8     Rd/Gn     ---     ---
9     Rd/Br    X05    slot 2 line 1/module line 5
10    Rd/Sl    X06    slot 2 line 2/Module line 6
11    Bk/Bl     ---     ---
12    Bk/Or     ---     ---
13    Bk/Gn    X07    slot 2 line 3/Module line 7
14    Bk/Br    X08    slot 2 line 4/Module line 8
15    Bk/Sl     ---     ---
16    Yl/Bl     ---     ---
17    Yl/Or    X09    slot 3 line 1/module line 9    
18    Yl/Gn    X10    slot 3 line 2/Module line 10    
19    Yl/Br     ---     ---    
20    Yl/Sl     ---     ---    
21    Vi/Bl    X11    slot 3 line 3/Module line 11    
22    Vi/Or    X12    slot 3 line 4/Module line 12    
23    Vi/Gn     ---     ---    
24    Vi/Br     ---     ---    
25    Vi/Sl     ---    Emergency Telephone    
                
Amphenol            trunk module    
Connector            E&M DISA Card    
Pair    Color    Port    Service    Line/Connection
1     Wh/Bl    X01    T    Slot 1 line 1/Module line 1
2     Wh/Or    X01    T1    Slot 1 line 1/Module line 1
3     Wh/Gn    X01    E    Slot 1 line 1/Module line 1
4     Wh/Br    X01    M    Slot 1 line 1/Module line 1
5     Wh/Sl    X02    T    slot 1 line 2 module line 2
6     Rd/Bl    X02    T1    slot 1 line 2 module line 2
7     Rd/Or    X02    E    slot 1 line 2 module line 2
8     Rd/Gn    X02    M    slot 1 line 2 module line 2
9     Rd/Br    X05    T    slot 2 line 1 module line 5
10    Rd/Sl    X05    T1    slot 2 line 1 module line 5
11    Bk/Bl    X05    E    slot 2 line 1 module line 5
12    Bk/Or    X05    M    slot 2 line 1 module line 5
13    Bk/Gn    X06    T    slot 2 line 2 module line 6
14    Bk/Br    X06    T1    slot 2 line 2 module line 6
15    Bk/Sl    X06    E    slot 2 line 2 module line 6
16    Yl/Bl    X06    M    slot 2 line 2 module line 6
17    Yl/Or    X09    T    slot 3 line 1 module line 9
18    Yl/Gn    X09    T1    slot 3 line 1 module line 9
19    Yl/Br    X09    E    slot 3 line 1 module line 9
20    Yl/Sl    X09    M    slot 3 line 1 module line 9
21    Vi/Bl    X10    T    slot 3 line 2 module line 10
22    Vi/Or    X10    T1    slot 3 line 2 module line 10
23    Vi/Gn    X10    E    slot 3 line 2 module line 10
24    Vi/Br    X10    M    slot 3 line 2 module line 10
25    Vi/Sl     ---     ---     ---
                
Amphenol            Trunk Module    
Connector            DID Card    
Pair    Color    Port    Line/Connection    
1     Wh/Bl    X01    slot 1 line 1/module line 1    
2     Wh/Or    X02    slot 1 line 2/module line 2    
3     Wh/Gn     ---     ---    
4     Wh/Br     ---    CCI NC1    
5     Wh/Sl    X03    slot 1 line 3/module line 3    
6     Rd/Bl    X04    slot 1 line 4/module line 4    
7     Rd/Or     ---     ---
8     Rd/Gn     ---     ---
9     Rd/Br    X05    slot 2 line 1/module line 1
10    Rd/Sl    X06    slot 2 line 2/module line 2
11    Bk/Bl     ---     ---
12    Bk/Or     ---    CCI NC1
13    Bk/Gn    X07    slot 2 line 3/module line 3
14    Bk/Br    X08    slot 2 line 4/module line 4
15    Bk/Sl     ---     ---
16    Yl/Bl     ---     ---
17    Yl/Or    X09    slot 3 line 1/module line 1
18    Yl/Gn    X10    slot 3 line 2/module line 2
19    Yl/Br     ---     ---
20    Yl/Sl     ---    CCI NC1
21    Vi/Bl    X11    slot 3 line 3/module line 3
22    Vi/Or    X12    slot 3 line 4/module line 4
23    Vi/Gn     ---     ---
24    Vi/Br     ---     ---
25    Vi/Sl     ---    Emergency Telephone
            
Amphenol            Trunk Module
Connector            BRI-ST Card
Pair    Color    Port    Line/Connection
1     Wh/Bl    X01    Slot 1 lines 001-002/Module lines 001-002/assigned DN
2     Wh/Or    X01    Slot 1 lines 001-002/Module lines 001-002/assigned DN
3     Wh/Gn    X02    Slot 1 lines 003-004//Module lines 003-004/assigned DN
4     Wh/Br    X02    Slot 1 lines 003-004//Module lines 003-004/assigned DN
5     Wh/Sl    X03    Slot 1 lines 005-006//Module lines 005-006/assigned DN
6     Rd/Bl    X03    Slot 1 lines 005-006//Module lines 005-006/assigned DN
7     Rd/Or    X04    Slot 1 lines 007-008//Module lines 007-008/assigned DN
8     Rd/Gn    X04    Slot 1 lines 007-008//Module lines 007-008/assigned DN
9     Rd/Br    X05    Slot 2 lines 001-002/Module lines 009-010/assigned DN
10    Rd/Sl    X05    Slot 2 lines 001-002/Module lines 009-010/assigned DN
11    Bk/Bl    X06    Slot 2 lines 003-004//Module lines 011-012/assigned DN
12    Bk/Or    X06    Slot 2 lines 003-004//Module lines 011-012/assigned DN
13    Bk/Gn    X07    Slot 2 lines 005-006//Module lines 013-014/assigned DN
14    Bk/Br    X07    Slot 2 lines 005-006//Module lines 013-014/assigned DN
15    Bk/Sl    X08    Slot 2 lines 007-008//Module lines 015-016/assigned DN
16    Yl/Bl    X08    Slot 2 lines 007-008//Module lines 015-016/assigned DN
17    Yl/Or    X09    Slot 3 lines 001-002/Module lines 017-018/assigned DN
18    Yl/Gn    X09    Slot 3 lines 001-002/Module lines 017-018/assigned DN
19    Yl/Br    X10    Slot 3 lines 003-004//Module lines 019-020/assigned DN
20    Yl/Sl    X10    Slot 3 lines 003-004//Module lines 019-020/assigned DN
21    Vi/Bl    X11    Slot 3 lines 005-006//Module lines 021-022/assigned DN
22    Vi/Or    X11    Slot 3 lines 005-006//Module lines 021-022/assigned DN
23    Vi/Gn    X12    Slot 4 lines 007-008//Module lines 023-024/assigned DN
24    Vi/Br    X12    Slot 4 lines 007-008//Module lines 023-024/assigned DN
25    Vi/Sl        
            
Amphenol            Trunk Module
Connector            BRI U Cards
Pair    Color    Port    U-NT/U-LT
1     Wh/Bl    X01    Slot 1 lines 001-002/Module lines 001-002/assigned DN
2     Wh/Or    X02    Slot 1 lines 003-004//Module lines 003-004/assigned DN
3     Wh/Gn     ---    
4     Wh/Br     ---    
5     Wh/Sl    X03    Slot 1 lines 005-006//Module lines 005-006/assigned DN
6     Rd/Bl    X04    Slot 1 lines 007-008//Module lines 007-008/assigned DN
7     Rd/Or     ---    
8     Rd/Gn     ---    
9     Rd/Br    X05    Slot 2 lines 001-002/Module lines 009-010/assigned DN
10    Rd/Sl    X06    Slot 2 lines 003-004//Module lines 011-012/assigned DN
11    Bk/Bl     ---    
12    Bk/Or     ---    
13    Bk/Gn    X07    Slot 2 lines 005-006//Module lines 013-014/assigned DN
14    Bk/Br    X08    Slot 2 lines 007-008//Module lines 015-016/assigned DN
15    Bk/Sl     ---     ---
16    Yl/Bl     ---     ---
17    Yl/Or    X09    Slot 3 lines 001-002/Module lines 017-018/assigned DN
18    Yl/Gn    X10    Slot 3 lines 003-004//Module lines 019-020/assigned DN
19    Yl/Br     ---     ---
20    Yl/Sl     ---     ---
21    Vi/Bl    X11    Slot 3 lines 005-006//Module lines 021-022/assigned DN
22    Vi/Or    X12    Slot 4 lines 007-008//Module lines 023-024/assigned DN
23    Vi/Gn     ---     ---
24    Vi/Br     ---     ---
25    Vi/Sl     ---     ---

Back to Nortel: Norstar systems FAQ Index
Back to Nortel: Norstar systems Forum

My Archive

Close Box

Join Tek-Tips® Today!

Join your peers on the Internet's largest technical computer professional community.
It's easy to join and it's free.

Here's Why Members Love Tek-Tips Forums:

Register now while it's still free!

Already a member? Close this window and log in.

Join Us             Close